to product sheet
Maximum Allowable Tolerances: Refer to
"Fabrication" section of specification
Shear test (ASTM D906-64)
| Temperature |
PSJ Sheer (average) |
| -35°C (-31°F) |
337 |
| 23°C ( 73°F) room temperature |
300 |
| 100°C (212°F) |
137 |
Peel test (ASTM D903-49, 1800 angle) At
23°C (73°F), 50 Ibs. linear peel
| Test |
Exposure |
Duration |
Results |
| High temperature |
95°C (203°F) |
30 days |
no bond failure |
| Hot/cold cycle |
1 hr. @ 95°C (203°F) |
4 cycles |
no bond failure |
| High temperature |
95°C (203°F) |
60 days |
bond good |
Deflection/Stress Test: Based on 120 mph
design wind velocity (38.88 Ibs./ft. sq.)
| Pane1 Size |
Total UDL (Ibs.) |
Deflection (in.) |
Stress (psi) |
| 4'-0" x 10'-0" |
1555 |
0.3155 |
2464 |
| 4'-0" x 6'-0" |
933 |
0.3017 |
2400 |
| 3'-6 5/8" x 6'-85/8" |
928 |
0.2586 |
2380 |
Fire Hazard Classification (CAN4-S102): Bears
label of Underwriters' Laboratories Inc. and Underwriters' Laboratories
of Canada.
| Finished Panel (anodized) |
Core Material (PVC) |
| Flame Spread- 0 {0 GWL) |
Flame Spread -20-25 {10-20 GWL) |
| Smoke Developed -10 |
Smoke Developed -350 |
| Fuel Contributed -0-10 |
Fuel Contributed- 0-5 |
Shear Peel and Deflection/Stress tests coducted by Ontario
Research Foundation, Ottawa, Ontario Fire Hazard Classification tests
conducted by ULI, Northbrook, Illinois and ULC Toronto, Ontario respectively.
Test reports available upon request.